HIU gas or electric: a heat interface unit is neither

Written by FM Power Plumbing and Heating Ltd with AI assistance ·

A heat interface unit (HIU) is neither a gas appliance nor an electric heater. It involves gas only indirectly, if the energy centre serving your building runs gas boilers, because the burning happens there and not in your flat. It uses electricity directly, because the unit needs a permanent 230 V supply for its controls, valves and pump. The heat itself arrives as hot water from the heat network.

HIU gas or electric: what each supply does in your flat

Neither supply makes the heat inside your flat on its own. Gas, where it is used at all, is burned in the building's energy centre, while the electricity at the HIU runs the controls and the pump.

CriterionGasElectricity
Connection at the unitNo gas connection is required at the HIU itself.A permanent electrical supply is required, or the unit will not run at all.
Where it is usedOnly in the central plant room or energy centre, if that plant is gas fired.At the HIU on your wall, for the electronics, the motorised valves and the pump.
What it providesThe fuel that may heat the network water upstream of your home.Power for the unit only. It does not generate the heat for your radiators or taps.
Combustion and flueNothing is burned inside the HIU, so the unit needs no flue.No combustion either, so no flue gas checks at the unit.
Who may work on itGas fittings in England are work for a Gas Safe registered engineer under GSIUR 1998.The HIU and its wiring are for competent persons, as the manufacturer's instructions require.
MeteringNo gas meter is involved in what you pay for heat.Separate from your heat charge, which comes from the heat meter at or in the HIU.

An HIU contains no burner, no gas valve and no flue. Any gas in the chain is burned in the building's energy centre, and the electricity at the unit powers controls and a pump, not the heating itself.

What a heat interface unit is and where its heat comes from

A heat interface unit is a wall-mounted unit inside a flat that takes heat from a shared heat network. Inside it sit plate heat exchangers, stacks of thin plates that pass heat from the network water across to your own heating water and your hot water. The network water never mixes with the water in your radiators or taps. The unit also keeps the two systems hydraulically separate, so the pressure in the network stays out of your flat.

Some units serve heating only, others handle heating and hot water, and some are supplied together with an indirect cylinder. Baxi states that an HIU has an annual maintenance need for safe and efficient operation, with the interval set by the manufacturer and the network operator rather than by the resident. If the flat has underfloor heating running off the HIU, the floor circuits raise their own version of this question, and underfloor heating: electric, wet or gas explains which type you are dealing with.

When gas is involved with an HIU: in the energy centre, not your flat

Gas enters the picture only where the heat is generated, which is normally a plant room or energy centre serving the whole block or estate. If that plant runs gas boilers, the burners, the gas pipework and the flues are all there, behind a locked door. Work on those gas fittings in England falls under the Gas Safety (Installation and Use) Regulations 1998 as amended. Regulation 3 requires anyone carrying out such work to be competent, which in practice means Gas Safe registered.

Your HIU has no burner, no gas valve and no gas supply. The one case where gas is still inside the flat is a separate appliance such as a gas cooker or a gas fire. Those are gas appliances in their own right, and the gas rules follow that appliance, not the HIU on the wall.

When electricity matters: the HIU runs on a 230 V supply

Electricity is what the heat interface unit itself runs on. Baxi states that an HIU requires a direct electrical supply, because the controls, the motorised valves and the pump all need power. Worcester Bosch specifies 230 V AC at 50 Hz for its Greenstar heat interface unit, single phase rather than three phase, with the unit earthed and wired as a fixed appliance to the current IET Wiring Regulations.

That power does not make your heat. It moves water and opens valves so that heat already in the network can cross into your flat. If the supply to the unit is off, the HIU can sit dead while the network outside is still hot. The electrical connection is work for a competent electrician, not a householder task, and it is outside what a plumbing and heating firm takes on.

Do you need a gas safety certificate for a flat with an HIU?

In England, a let flat whose only heat source is an HIU normally needs no annual gas safety check, because there is no gas appliance in it to check. The duty under the Gas Safety (Installation and Use) Regulations 1998 as amended attaches to relevant gas appliances and flues in the property. HSE is clear that where none are present the annual check does not arise. Gas pipework left in the property still has to be kept in a safe condition, so the duty does not disappear entirely.

As soon as a gas cooker, hob or fire is in the flat, the annual check applies to that appliance and a record follows. The position for a property with pipework but no appliances is set out in gas safety certificate with no gas appliances. In a block with a communal plant room, the boilers there are a separate duty on whoever controls them, which is explained in gas safety in a leasehold flat.

No heating or hot water from your HIU: what you can check yourself

When a heat interface unit gives no heating or hot water, four things are safe for a householder to look at. Check the room thermostat and the programmer, including the clock and the hot water schedule. Read the pressure gauge on your own heating side and note what it shows. Press the reset button if the unit has one and the user instructions describe it, and bleed a radiator that is cold at the top.

Everything else belongs to someone else. The inside of the casing, the plate heat exchangers, the valves on the network side and the electrical supply are for a competent engineer or the network operator, as the manufacturer's instructions state. What a falling gauge usually means is covered in boiler low pressure: what the gauge is telling you. GOV.UK advises heat network customers to contact their heat supplier first, and to establish before moving in who to call, what the response arrangements are and what happens during an unplanned outage.

Can you replace an HIU with a gas boiler?

Swapping an HIU for a gas boiler is rarely a decision a resident can take alone. Government material on heat networks notes that customers on a network generally cannot switch heat supplier or install their own heat source, and that this is often written into the supply contract. A lease usually adds its own restrictions on altering building services. A new boiler would also need a flue route out through the building, which in a flat is often the hardest part.

Where such a change is permitted, the gas side remains regulated work. In England, installing a gas boiler is work in relation to gas fittings under the Gas Safety (Installation and Use) Regulations 1998 as amended, so it is for a Gas Safe registered engineer. The consent question in a leasehold flat is set out in freeholder permission to replace a boiler.

Gas or electric: which answer fits your flat with an HIU

Say gas, if you are asking where the heat ultimately comes from and your building's energy centre runs gas boilers. The burning happens there, under gas regulation, and never inside the unit on your wall. Say electric, if you are asking what the HIU itself needs to run, because it takes a 230 V supply for its controls, valves and pump and nothing more.

Say neither, if the question is really about safety paperwork. An HIU is not a gas appliance, so it does not appear on a gas safety record, and it has no flue to inspect. If a gas cooker, gas fire or gas boiler is also in the home, that appliance decides what applies, not the HIU. If your property has a gas boiler as well, or you are moving from a heat network back to one, our page on boiler service and repairs sets out what that work covers.

Sources

Common questions

Does an HIU need a flue?

No. Worcester Bosch states that a heat interface unit does not burn any gases inside the unit and that the heat is supplied by a district heating source, so no flue is required. That is one of the clearest differences between an HIU and a gas combi boiler in a flat.

Do I still need a CP12 if my flat has an HIU and a gas cooker?

Yes, for the cooker. In England the landlord duty under the Gas Safety (Installation and Use) Regulations 1998 as amended follows the gas appliance, and a cooker is one. The HIU is not a gas appliance and does not appear on the record as one.

Who do I contact if my HIU gives no heating or hot water?

Contact your heat supplier first; GOV.UK gives that as the route for heat network customers. Your contract sets out who maintains the HIU inside the flat and what the response arrangements are. Ofgem has regulated heat networks in Great Britain since the authorisation conditions took effect on 27 January 2026 and publishes advice for customers.

Why is there a heat meter on my HIU?

The Heat Network (Metering and Billing) Regulations 2014 place a duty on heat suppliers to install meters for final customers and to bill on measured consumption. The meter is normally fitted at or inside the HIU, which is why residents often think the HIU is the meter. The duty sits with the heat supplier, not with you.

Is a heat interface unit the same as a hydraulic interface unit?

The two terms are used loosely and Baxi keeps a separate entry for each. Both describe a unit that links a central heat source to a property's own heating and hot water circuits while keeping them hydraulically separate. In flats on a heat network, the usual term in product literature and billing is heat interface unit, or HIU.

Rather have someone look at it?

We are Gas Safe registered and work across London & surrounding areas. Call or WhatsApp any time — we answer 24/7. Tell us what you need and where you are, and we will tell you what it involves and what it is likely to cost before anyone comes out.

Get in touch

Fastest way to reach us is a call or WhatsApp, we answer 24/7 — send a photo of the job and we will come back with a price. Prefer email? Use the form and we will reply as soon as we are off site.

Request a free quote

Tell us about the job — no obligation, no pushy sales call.

Your details are only used to answer your enquiry.

Boiler repairs · reachable at night for emergencies