Megaflo hot water pressure drops after a few minutes: flow or temperature?

Written by FM Power Plumbing and Heating Ltd with AI assistance ·

Hot water from a Megaflo or other unvented cylinder that fades after a minute or two is two separate problems, and the tap tells you which one you have. If the stream thins while the water stays hot, the cold mains side is the place to look: supply pressure, the strainer in the inlet group, the expansion volume. If the stream holds its force while the water turns cool, the stored volume or the reheat is behind it, and pressure is not the issue at all.

Flow drops but water stays hot, or flow holds but water turns cool: how the two patterns differ

Hot water from a Megaflo or other unvented cylinder fades in two different ways, and each one leads to a different part of the system. Watch what the tap does over the first two minutes and compare the two columns.

CriterionFlow drops, water stays hotFlow holds, water turns cool
What changes at the tapThe stream thins while the temperature stays where it was.The stream keeps its force while the temperature slides down.
Cold water at the same mixerOften weak too: the balanced cold take-off feeds mixers from the same inlet group as the hot.Cold is unchanged; only the hot side loses temperature.
Parts an engineer looks atCold mains supply, the pressure reducing valve and its strainer, and the expansion volume inside the cylinder.Stored volume in use, the heat source and its controls, the blending valve and air in the reheat coil.
Supply figures that matterMegaflo Eco quotes 1.5 bar and 20 litres per minute as the minimum cold supply; at those values flow can be poor with two outlets open.Supply figures do not explain it; cylinder size against the amount of hot water drawn does.
A clue the manufacturer namesIntermittent discharge at the expansion valve is listed by the maker as a sign the air volume has been lost.Maker fault lists point to the mixer setting, the heat source, the controls and reversed hot and cold connections.

The balanced cold take-off is the cold feed drawn off inside the cylinder's inlet group, between the 3.5 bar pressure reducing valve and the 8 bar expansion relief valve. It serves showers and mixer taps so hot and cold arrive at a matched pressure. A restriction before the cylinder can therefore weaken both sides of a shower at the same time.

When the flow drops while the water stays hot on an unvented cylinder

A stream that thins within a minute or two while the water stays hot points to the cold mains side of your unvented cylinder, not to the stored water. The cylinder still has hot water in it. What has changed is how much water can get through to the tap.

  • A supply close to the minimum. Heatrae Sadia gives 1.5 bar working pressure and 20 litres per minute as the minimum cold supply for domestic Megaflo Eco sizes. The manual adds that outlet flow rates may be poor at those values if several outlets run at once.
  • A second outlet opening. The shower is full for the first minute, then someone runs the kitchen tap and the shower thins.
  • A blocked strainer. Manufacturer fault tables list a blocked strainer in the pressure reducing valve behind poor or absent hot water. Where the mains carries suspended solids, the maker requires adequate filtration because the strainer can silt up.
  • A lost air charge. The expansion volume loses air over the years, and intermittent discharge at the expansion valve is the sign the maker names. More on that in our guide to an unvented cylinder expansion vessel losing its charge.

One mechanical explanation is that stored pressure carries the first seconds, after which the flow settles back to what the incoming main really delivers. Treat that as a possible explanation, not a diagnosis. Only a test of the supply and the inlet group settles it.

When the flow holds steady but the water from the cylinder turns cool

Water that cools while the stream keeps its force means the hot store or the reheat has run short, not the pressure. The tap is still delivering the same number of litres per minute. What drops is temperature.

  • Two draws close together. A bath followed by a shower, or two showers back to back, can empty a store sized for a smaller demand. Our guide on what size hot water cylinder you need sets out how volume is matched to a household.
  • The heat source is not reheating. Manufacturer fault lists name a heat source that fails to reheat and a faulty external control among the causes of a low blended temperature.
  • The blending valve is set low. A mixer thermostat set too low gives lukewarm water at the tap even with a full cylinder.
  • Air in the reheat coil, or reversed connections. Hot and cold connections swapped at the cylinder appear in the same fault lists, which matters after recent work on the system.

Manufacturers are explicit that the occupant should not alter the blending valve setting. Where the temperature at the tap is too high or too low, they say to call an engineer qualified on unvented hot water systems.

What you can check yourself before calling out an engineer to the cylinder

Four checks are safe for a householder: the boiler pressure gauge, the thermostat and programmer settings, the reset button, and bleeding radiators. None of them restores flow at an unvented cylinder, so be honest with yourself about what they can show.

The programmer is still worth a look in the cooling case. A hot water period that ends mid-morning leaves the store with nothing to reheat it before the evening. The cylinder thermostat setting is worth reading off at the same time.

Everything on the cylinder itself is engineer work: the strainer, the pressure reducing valve cartridge, the expansion volume, the safety valves and the blending valve. Recharging the air volume is done only with the system depressurised, and the maker warns against overcharging. Ask for an engineer qualified on unvented hot water systems, and where a gas boiler heats the coil, a Gas Safe registered one for anything on the boiler, the flue or inside the casing.

What the rules in England require for an unvented hot water cylinder

Unvented hot water systems in England sit under Part G3 of Schedule 1 to the Building Regulations 2010. G3 requires the system to withstand the temperatures and pressures of normal use and of reasonably anticipated malfunction. Stored water must be prevented from exceeding 100 degrees Celsius, any discharge must be visible and safely carried away, and hot water at a fixed bath must not exceed 48 degrees Celsius.

Approved Document G, in the version with the 2024 amendments and marked for use in England, adds the detail. Unvented systems up to 500 litres and under 45 kW should be a proprietary unit or package. They should carry at least two independent safety devices in addition to the thermostat.

Notification follows the installer. If the installer is not registered on a competent person scheme for unvented hot water, the building control body must be told before the work. A registered installer self-certifies, the owner receives a Building Regulations compliance certificate, and completion is notified within 30 days.

Manufacturers also set an annual service by a competent person, covering the safety valves, the strainer element and the air volume, to avoid faults in operation. Our guide on servicing unvented cylinders and Megaflo systems goes through what that visit covers.

Which of the two to report: flow drop, if the stream thins; cooling water, if only the heat fades

Report a flow drop if the stream thins within a minute or two while the water stays hot, and particularly if the cold side of the same mixer weakens with it or the expansion valve has been discharging on and off. That version sends the engineer to the supply, the inlet group strainer and the expansion volume.

Report cooling water if the stream never changes and the water only goes lukewarm, typically after a bath or a second shower. That version sends the engineer to the stored volume, the heat source, its controls and the blending valve.

If both happen together, say so rather than choosing one. A thinning stream and cooling water can sit side by side, and the engineer can then look at the supply and the store in the same visit. Note the time of day and which outlets were running, since that detail narrows it down.

Where the cylinder itself is at the end of its life and a replacement is on the table, a free home survey comes first and a written fixed price follows: see Megaflo and unvented systems.

Sources

Common questions

Is a strong burst at the start normal on a Megaflo?

Yes. Heatrae Sadia describes a small surge in flow when hot outlets are opened, while the pressures settle, and calls it normal on unvented systems. That is a rise at the very start. A stream that fades after a minute or two is a different pattern and worth reporting.

Why does the cold water weaken at the same time as the hot?

Mixer taps and showers are fed from the balanced cold take-off, drawn off between the 3.5 bar pressure reducing valve and the 8 bar expansion relief valve. Hot and cold therefore share the same inlet group. A restriction before the cylinder shows up on both sides at once.

Can limescale in the coil cause the flow to drop?

We will not claim that without a manufacturer source to back it. What the manuals do name is a blocked strainer in the pressure reducing valve, and a requirement for adequate filtration where the mains carries suspended solids. Ask an engineer qualified on unvented systems to check the inlet group.

Does an unvented cylinder need an annual service?

Manufacturers set an annual service by a competent person as a condition of safe operation and full performance. It covers checking and manually opening the safety valves, cleaning the strainer element and renewing the air volume. The makers state it is done to avoid faults in operation.

Can any plumber work on my unvented cylinder?

Work on an unvented system belongs to someone qualified for it, and in England the installer's competent person registration also decides how the work is notified. Where a gas boiler heats the coil, the Gas Safety (Installation and Use) Regulations 1998 as amended apply across Great Britain and the engineer must be Gas Safe registered. HSE advises asking to see the card, with the photo, registration number and expiry date on the front.

Do I need building control paperwork if the cylinder is replaced in England?

Yes. If the installer is not on a competent person scheme for unvented hot water, the building control body must be informed before the installation. A registered installer self-certifies instead, you receive a Building Regulations compliance certificate, and completion is notified within 30 days.

Rather have someone look at it?

We are Gas Safe registered and work across London & surrounding areas. Call or WhatsApp any time — we answer 24/7. Tell us what you need and where you are, and we will tell you what it involves and what it is likely to cost before anyone comes out.

Get in touch

Fastest way to reach us is a call or WhatsApp, we answer 24/7 — send a photo of the job and we will come back with a price. Prefer email? Use the form and we will reply as soon as we are off site.

Request a free quote

Tell us about the job — no obligation, no pushy sales call.

Your details are only used to answer your enquiry.

Gas Safe registered · we answer 24/7